Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Rev. argent. cardiol ; 87(3): 197-202, mayo 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1057342

ABSTRACT

RESUMEN Introducción: La Sociedad Europea de Cardiología recomienda para la evaluación del dolor torácico un algoritmo con medición seriada de dos troponinas de alta sensibilidad separadas por una hora. Sin embargo, la alta eficacia y seguridad solo se han estimado según supuestos basados en modelos teóricos. Probamos por primera vez su desempeño en nuestro medio cuando se integra en la rutina diaria. Métodos: Estudio prospectivo unicéntrico que incluyó a pacientes no seleccionados que presentaban sospecha de infarto sin elevación del ST en el servicio de emergencias, a los que se les practicó el algoritmo SEC 0/1h utilizando troponina T de alta sensiblidad. Se evaluó el comportamiento en términos de incidencia a 30 días de los eventos de infarto agudo de miocardio, muerte cardiovascular y el combinado de infarto agudo de miocardio, muerte o revascularización coronaria. Resultados: Se incluyeron 1351 pacientes con una edad media de 61 ± 14 años, 12,4% de diabéticos y 35,8% de evento coronario previo. La tasa de infarto agudo de miocardio fue del 11% con una mortalidad del 0,29%. De acuerdo con la aplicación del algoritmo, 917 pacientes fueron catalogados como "externar" (67%); 270, como "observar" (20%); y 164, como "internar" (13%). La tasa del evento infarto agudo de miocardio resultó del 0,3% en "externar"; del 7%, en "observar"; y del 77,4%, en "internar" (p < 0,001). Por su lado, la muerte o revascularización coronaria resultó de 7,7% en "externar"; del 17,7%, en "observar"; y del 80,4%, en "internar" (p < 0,001). Conclusiones: El algoritmo de 1 hora presentó una buena capacidad para estratificar a pacientes que consultan con sospecha de infarto agudo de miocardio con un gran valor predictivo negativo para excluir el evento de infarto a los 30 días, aunque dicho valor disminuye cuando el evento considerado es la necesidad de revascularización coronaria.


ABSTRACT Background: The European Society of Cardiology (ESC) recommends an algorithm for the evaluation of chest pain with serial measurement of two high sensitivity troponins separated by one hour. However, the high efficacy and safety of the algorithm has only been estimated according to assumptions based on theoretical models. We tested for the first time its performance in the real world by incorporating it into the daily routine of our center. Methods: This is a prospective, single center study using the ESC 0/1h algorithm with high sensitivity troponin T on unselected patients who presented at the emergency department with suspected non-ST-segment elevation acute myocardial infarction. Efficacy and safety were assessed in terms of the 30-day incidence of acute myocardial infarction, cardiovascular death and the composite of acute myocardial infarction, death or coronary revascularization. Results: A total of 1,351 patients were included in the study. Mean age was 61±14 years, 12.4% were diabetics and 35.8% had previous history of coronary events. The rate of acute myocardial infarction was 11% and the rate of mortality 0.29%. According to the application of the algorithm, 917 patients were catalogued as "rule out" (67%), 270 as "observe" (20%) and 164 as "rule in" (13%). The rate of acute myocardial infarction was 0.3% in "rule out", 7% in "observe" and 77.4% in "rule in" (p <0.001). Moreover, death or coronary revascularization was 7.7% in "rule out", 17.7% in "observe" and 80.4% in "rule in" (p <0.001). Conclusions: The 1-hour algorithm showed a good capacity to stratify patients presenting with suspicion of acute myocardial infarction and a high negative predictive value to exclude infarction at 30 days, although this capacity decreases when the event considered is the need for coronary revascularization.

2.
Prensa méd. argent ; 104(6): 299-302, Ago2018. fig
Article in Spanish | LILACS, BINACIS | ID: biblio-1051347

ABSTRACT

Presentamos un paciente joven con miocardiopatía hipertrófica y altos umbrales de desfibrilación que necesitó recambio de generador por agotamiento. Durante el procedimiento utilizando un desfibrilador de alta salida y luego de probar varios cambios de configuración no fue efectiva la terminación de la FV inducida por lo que requiere la colocación de un catéter de desfibrilación subcutáneo con lo que se lograron adecuados márgenes de seguridad. Se realiza una revisión de la literatura acerca de las opciones en casos de altos umbrales de desfibrilación


We present a young patient with hypertrophic cardiomyopathy and high defibrillation thresholds that needed a generatior replacement. During the procedure, a high-output defibrillator was not effective for the termination of induced ventricular fibrillation (FV), even after testing several configurations. Alternatively, safety margin were reached by placing a subcutaneous defibrillator catheter. A literature review is performed exploring options for cases where defibrillation thresholds are high


Subject(s)
Humans , Adult , Cardiomyopathy, Hypertrophic/pathology , Defibrillators, Implantable , Threshold Limit Values , Cardiac Catheters
SELECTION OF CITATIONS
SEARCH DETAIL